EV Chargers

360-960kW Split Type DC Charger (Dynamic Power Distribution)

YLCED series split type charging station covers 360kW~960kW, output covers 6~24 terminals, and the system adopts dynamic power distribution technology to greatly improve the utilization rate of charging power. The system supports optional air-cooling terminal and liquid-cooling supercharging terminal, providing solutions for supercharging in different scenarios.

Category

YLCED series split type charging station covers 360kW~960kW, output covers 6~24 terminals, and the system adopts dynamic power distribution technology to greatly improve the utilization rate of charging power. The system supports optional air-cooling terminal and liquid-cooling supercharging terminal, providing solutions for supercharging in different scenarios.

• Main platforms are fully compatible, more than 60 platforms have been accessed, support one-click switching platforms without program updating.
• Support remote fault diagnosis, OTA upgrade for controllers, etc.
• Support various payment methods.
• Glue filling/non-glue filling modules available to provide more options for the full charging scenarios.
• DC output range of 200–1000V, system power capacity ranging from 30 to 960 kW, suitable for a wide range of electric vehicles.
• Excellent high temperature performance, ensure full load operation and fast charging.
• Multi-region linkage sampling ensures comprehensive data collection across diverse environments, safeguarding system integrity and performance.
• Power cabinet and charging terminal split design, terminal with small size, low noise, friendly HMI.
• Dynamic power distribution greatly improve the power utilization.
• 250kW terminal/600kW liquid-cooled super terminal available.

Item Cabinet parameters
Basic index
Model YLCES360K YLCES480K YLCES640K YLCES720K YLCES960K
Rated power 360KW 480KW 640KW 720KW 960KW
Max number of access terminals 6 12 12 12 24
Cooling method Fan cooling
Liquid-cooling terminal Optional
Dimensions (WxDxH) 1000x800x1850mm 1300x800x1950mm 2000x800x1850mm 2000x800x1850mm 2620x800x1950mm
Weight (KG) 550 690 1120 1160 1380
Input
Voltage 380VAC ±15%, 3P+N+PE
Frequency 45Hz-65Hz
Current 582A 773A 1031A 1160A 1547A
power factor ≥ 0.99
iTHD ≤ 5%
Output
Output voltage 200-1000Vdc
Constant power range 300-1000Vdc
Max efficiency 95%
Output voltage error ≤ ±0.5%
Output current error ≤ ±1%
Voltage stabilized accuracy ≤ ±0.5%
Current stabilized accuracy ≤ ±1%
Peak-peak ripple ≤ ±1%
Environment
Operating temperature -20 ~ +50°C
Storage temperature -40 ~ +75°C
Humidity 5-95%RH, non-condensing
Altitude 2000m no derating required; >2000m, the working temperature decreases by 1°C for every 100m rise
Item Terminal parameters
Basic index Model YLCLT600K YLCLT250K
Rated power 600KW 250KW
No. of access terminals 1 2
Cable length 3.5m/5m 5m (customized)
Cooling method Liquid-cooling Fan cooling
Dimensions (WxDxH) 650mm x 350mm x 1750mm 450mm x 200mm x 1600mm
Weight (KG) 150 100 (dual), 80 (single)
HMI 7-inch color screen
Start-up method RFID/Credit Card/VIN/Plug&charge/Scan QR code (optional)
Output Platform communication Ethernet/4G
Current range (air-cooling) 0-250A per plug
Current range (liquid-cooling) 0-600A per plug
Output voltage 200-1000Vdc
Constant power range 300-1000Vdc
Max efficiency >95%
Output voltage error ≤ ±0.5%
Output current error ≤ ±1%
Peak-peak ripple ≤ ±1%
Environment Operating temperature -20 ~ +50°C
Storage temperature -40 ~ +75°C
Operating environment Indoor or outdoor (IP54)
Humidity 5-95%RH, non-condensing
Altitude 2000m no derating required; >2000m, the working temperature decreases by 1°C for every 100m rise

 